{"product_id":"excel-100-080","title":"Excel 100-080 Cat6 U\/UTP 24AWG Cable 305Mtr Price in Dubai UAE","description":"\u003ctable class=\"spec_table\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"mobile depth_1\"\u003e\n\u003cth colspan=\"3\" scope=\"col\"\u003e\n\u003cdiv class=\"\"\u003eSpecifications\u003c\/div\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody data-start=\"324\" data-end=\"4792\"\u003e\n\u003ctr data-start=\"324\" data-end=\"435\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"326\" data-end=\"342\"\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExcel 100-080 Cat6 U\/UTP 24AWG Cable 305Mtr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"436\" data-end=\"547\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"438\" data-end=\"447\"\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExcel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"548\" data-end=\"659\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"550\" data-end=\"566\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNetworking Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"660\" data-end=\"772\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"662\" data-end=\"676\"\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 6 (Cat 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"773\" data-end=\"886\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"775\" data-end=\"793\"\u003eConductor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24AWG (American Wire Gauge) Solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"887\" data-end=\"998\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"889\" data-end=\"911\"\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU\/UTP (Unshielded\/Unshielded Twisted Pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"999\" data-end=\"1110\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1001\" data-end=\"1026\"\u003eCable Jacket Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC (Polyvinyl Chloride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1111\" data-end=\"1222\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1113\" data-end=\"1129\"\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 meters (1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1223\" data-end=\"1335\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1225\" data-end=\"1240\"\u003eCable Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUsually Blue (depends on specific batch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1336\" data-end=\"1448\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1338\" data-end=\"1360\"\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper (Pure copper conductors for optimal performance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1449\" data-end=\"1561\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1451\" data-end=\"1473\"\u003eBandwidth Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 250 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1562\" data-end=\"1673\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1564\" data-end=\"1587\"\u003eData Transfer Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps (Gigabit Ethernet, ideal for high-speed networking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1674\" data-end=\"1784\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1676\" data-end=\"1697\"\u003eTransmission Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1785\" data-end=\"1896\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1787\" data-end=\"1800\"\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU\/UTP (No shielding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1897\" data-end=\"2009\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"1899\" data-end=\"1912\"\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ohms ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2010\" data-end=\"2122\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2012\" data-end=\"2032\"\u003eFlame Retardancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (standard PVC jacket, not LSOH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2234\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2125\" data-end=\"2146\"\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating temperature range: -20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2235\" data-end=\"2346\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2237\" data-end=\"2252\"\u003eFire Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard PVC (not Low Smoke Zero Halogen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2458\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2349\" data-end=\"2371\"\u003eMax Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Amps per conductor (depending on usage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2572\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2461\" data-end=\"2485\"\u003eStandards Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– ISO\/IEC 11801 Class E, TIA\/EIA-568-C.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2573\" data-end=\"2685\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2575\" data-end=\"2592\"\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoHS Compliant, UL (Underwriters Laboratories)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2686\" data-end=\"2798\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"2688\" data-end=\"2715\"\u003eCompatible Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– Ethernet Networks (Gigabit Ethernet, 100BASE-TX, 1000BASE-T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2799\" data-end=\"2909\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– Data Centers and Server Rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2910\" data-end=\"3020\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– Telecom and Broadband Applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3021\" data-end=\"3131\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– CCTV (Closed Circuit Television) Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3132\" data-end=\"3301\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"3134\" data-end=\"3146\"\u003eUse Case\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIdeal for general networking purposes where high-speed data transmission is required, such as in offices, buildings, and data centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3302\" data-end=\"3414\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"3304\" data-end=\"3328\"\u003ePerformance Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat 6, supporting Gigabit Ethernet and Fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3415\" data-end=\"3527\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"3417\" data-end=\"3433\"\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– Data transmission for LAN, WAN, and internet connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3528\" data-end=\"3637\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– Backbone installations in large networks (offices, buildings, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3638\" data-end=\"3748\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– High-speed data communication environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3749\" data-end=\"3862\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"3751\" data-end=\"3779\"\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– Resistant to environmental factors like temperature and humidity variations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3863\" data-end=\"3984\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– Suitable for use in less interference-prone environments compared to shielded cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3985\" data-end=\"4104\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"3987\" data-end=\"3999\"\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– High-performance cable for Gigabit Ethernet and other high-speed networking needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4105\" data-end=\"4215\"\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e– PVC jacket for general-purpose installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4216\" data-end=\"4328\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"4218\" data-end=\"4231\"\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305 Meter Cable in a roll (approximately 1000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4329\" data-end=\"4443\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"4331\" data-end=\"4349\"\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 15 kg (varies slightly depending on the packaging and roll size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4444\" data-end=\"4556\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"4446\" data-end=\"4464\"\u003eOuter Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 5.9mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4557\" data-end=\"4679\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"4559\" data-end=\"4586\"\u003eApplication Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e– Indoor usage in controlled environments such as offices, buildings, and data centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4680\" data-end=\"4792\"\u003e\n\u003ctd\u003e\u003cstrong data-start=\"4682\" data-end=\"4709\"\u003eProtection Against Fire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, with PVC jacket (standard fire-resistant properties)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Excel","offers":[{"title":"CAT6 \/ U\/UTP \/ 23AWG","offer_id":46369452654766,"sku":"100-080","price":0.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/9630\/8398\/files\/100-080.jpg?v=1744004999","url":"https:\/\/cablesandswitches.com\/products\/excel-100-080","provider":"Cables\u0026Switches","version":"1.0","type":"link"}