Datacom DC-FO-24-TB50-INZH-M3 Indoor/Outdoor-Loose Tube-LSZH Jacket Price in Dubai, UAE
GENERAL SPECIFICATIONS
|
|
Cable Type |
LSZH Tight buffer |
Total Fiber Count |
6 |
Outer Jacket Color |
Yellow |
Strength Members |
Aramid Yarns |
Diameter Over Jacket |
5.5 mm ± 0.5 |
Fiber Type |
Single Mode |
Color Coding |
Blue, Orange, Green, Brown, Slate & White |
Cable Weight (Kg/Km) |
26 ± 10% |
Standard Length (meters) |
2000 ± 5% |
|
|
Attenuation at 1310 nm (dB/Km) for SMF Cable |
≤ 0.38 |
Attenuation at 1550 nm (dB/Km) for SMF Cable |
≤ 0.26 |
Attenuation at 850 nm (dB/Km) for SMF Cable |
≤ 3.5 |
Attenuation at 1300 nm (dB/Km) for SMF Cable |
≤ 1.5 |
|
|
Temperature Range (°C) [IEC 60794-1-2-F1] |
Operation: -20 °C to +70 °C, Installation: -5 °C to +45 °C & Storage: -20 °C to +70 °C |
Cable Bending Radius (mm) [IEC 60794-1-2-E11 A] |
20 x D, D = Cable Diameter |
Kink Resistance (mm) [IEC 60794-1-2-E10] |
10 x D, D = Cable Diameter |
Tensile Force [IEC 60794-1-2-E1] |
600 N |
Impact Resistance [IEC 60794-1-2-E4] |
Height 0.5 meters, Weight = 0.5 Kg, 3 Nos |
Repeated Bending [IEC 60794-1-2-E6] |
30 Cycle, r = 20 X D, 1 Kg Load, D = Cable Diameter |
Crush Resistance [IEC 60794-1-2-E3] |
600 N [100 X 100 mm] for 60 sec |
Torsion Resistance [IEC 60794-1-2-E7] |
10 Cycle [±180°] 1Kg Weight, Length under Test-2M |
Flame test [IEC 60332-1-2] |
Should Pass |
Datacom DC-FO-24-TB50-INZH-M3 Indoor/Outdoor-Loose Tube-LSZH Jacket Price in Dubai, UAE
Adding product to your cart
You may also like
GENERAL SPECIFICATIONS
|
|
Cable Type |
LSZH Tight buffer |
Total Fiber Count |
6 |
Outer Jacket Color |
Yellow |
Strength Members |
Aramid Yarns |
Diameter Over Jacket |
5.5 mm ± 0.5 |
Fiber Type |
Single Mode |
Color Coding |
Blue, Orange, Green, Brown, Slate & White |
Cable Weight (Kg/Km) |
26 ± 10% |
Standard Length (meters) |
2000 ± 5% |
|
|
Attenuation at 1310 nm (dB/Km) for SMF Cable |
≤ 0.38 |
Attenuation at 1550 nm (dB/Km) for SMF Cable |
≤ 0.26 |
Attenuation at 850 nm (dB/Km) for SMF Cable |
≤ 3.5 |
Attenuation at 1300 nm (dB/Km) for SMF Cable |
≤ 1.5 |
|
|
Temperature Range (°C) [IEC 60794-1-2-F1] |
Operation: -20 °C to +70 °C, Installation: -5 °C to +45 °C & Storage: -20 °C to +70 °C |
Cable Bending Radius (mm) [IEC 60794-1-2-E11 A] |
20 x D, D = Cable Diameter |
Kink Resistance (mm) [IEC 60794-1-2-E10] |
10 x D, D = Cable Diameter |
Tensile Force [IEC 60794-1-2-E1] |
600 N |
Impact Resistance [IEC 60794-1-2-E4] |
Height 0.5 meters, Weight = 0.5 Kg, 3 Nos |
Repeated Bending [IEC 60794-1-2-E6] |
30 Cycle, r = 20 X D, 1 Kg Load, D = Cable Diameter |
Crush Resistance [IEC 60794-1-2-E3] |
600 N [100 X 100 mm] for 60 sec |
Torsion Resistance [IEC 60794-1-2-E7] |
10 Cycle [±180°] 1Kg Weight, Length under Test-2M |
Flame test [IEC 60332-1-2] |
Should Pass |